As what mentioned the southwire type has three conductors.
Uf b wire uses.
I would feed the uf b cable into the conduit and terminate in the panel cb.
Although nm cable is covered with a flexible thermoplastic covering on the outside of the wiring the strands of wire themselves are usually protected with little more than a paper wrapper.
Uf b wire s formal name refers to its uses.
View the southwire company 100 ft.
Uf b has a heat capacity of 90 c and is rated at 600 volt.
I would then run the uf b cable along the bottom of the deck.
An example is the uf b 8 3 and the uf b 14 3.
I want to use non metallic conduit from the bottom of the panel to reach under my elevated deck about 5 ft.
Uf b cable is typically used as an underground feeder cable to distribute power from an existing building to outdoor lighting fixtures pumps outbuildings and other outdoor equipment.
The cable is ul listed and suitable for operation at 600 volts in almost all installations as specified by the national electrical code.
Uf b underground feeder cable is usually manufactured as a two or three conductor cable with or without a ground wire.
U nderground f eeder and b ranch circuit wiring cable.
On the other hand uf cable utilizes solid thermoplastic exterior.
It can also be used for outbuildings such as garages and barns.
Underground feeder building wire assortment 112 69 1 13 ft 112 69 1 13 ft free delivery.
While standard nm cable is rated only for dry interior applications uf cable can be used outdoors as well as indoors.
Both type uf and type uf b cables are available in different common wire sizes also known as gauges and common wire counts.
Uf b feeds from a distribution point in an existing building.
The weight per 1 000 feet is 303 pounds and the ground wire size is 10.
Southwire s copper uf b cable is used in applications southwire s copper uf b cable is used in applications that include outside lamp posts pumps and other loads.
For example if you want to install a cable between the house and an outdoor lamppost or to run power out to a garden shed or detached garage uf cable is the standard choice.
The cable can also be used as direct burial cable.
100 ft 12 2 uf wire by the roll item 70020 model 13055926.
The most significant difference between nm cable and uf electric wire is the type of sheathing that is used.
The former is 8 awg and with 3 conductors.
Set your store to see local availability add to cart.
For example a 12 gauge wire with a hot and a neutral black and white wire and a ground would be considered a 12 2 uf wire cable.
I further plan to use uf b cable.
It has seven strands with a ground wire size of 10.